Diagnostic information 2-189
7510
100K maintenance required
600K maintenance required
2
Check the switch (printer left lower door interlock) for
operation.
1. Enter the Diagnostics Menu.
2. Touch BASE SENSOR TEST.
3. Touch Cover and Door.
4. Touch Door B left/lower.
Does the display on the operator panel change every time
the actuator on the above switch is operated?
Go to step 4. Go to step 3.
3
Check the switch (printer left lower door interlock)
connection.
Is the above component properly connected?
Replace the switch
(printer left lower
door interlock).
Go to “Switch
(printer left door
interlock)
removal” on
page 4-19.
Replace the
connection.
4
Perform a print test.
Does the error continue when the power is turned off/on?
Replace the upper
printer engine card
assembly.
Go to “Upper
printer engine
card assembly
removal” on
page 4-77.
Problem solved.
Step Check Yes No
1 Install the 100K maintenance kit.
Does the message still occur?
Reset the 100K
maintenance
counter.
Go to “Scheduled
maintenance” on
page 6-3.
Problem solved.
Step Check Yes No
1 Install the 600K maintenance kit.
Does the message still occur?
Reset the 600K
maintenance
counter.
Go to “Scheduled
maintenance” on
page 6-3.
Problem solved.
Step Check Yes No