2-94 Service Manual
7510
7
Check the sensor (ADF registration) for proper connection.
Is the above component properly connected?
Replace the
sensor (ADF
registration).
Go to “Sensor
(ADF inverter)
removal” on
page 4-151.
Replace the
connection.
8
Check the inverter gate condition.
Is the inverter gate free of damage and warpage and does it
move smoothly?
Go to step 9. Replace the
inverter gate.
Go to “Inverter
gate removal” on
page 4-152.
9
Check the ADF registration motor for proper operation.
Caution: When performing motor tests,
ensure that all cover and door interlock
switches are overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Scanner Motor Tests.
4. Touch ADF registration drv mtr.
5. Touch Forward or reverse.
Does the above component operate properly?
Go to step 11. Go to step 10.
10
Check the ADF registration motor for proper connection.
Is the above component properly connected?
Replace the ADF
registration
motor.
Go to “ADF
registration
motor removal”
on page 4-159.
Replace the
connection.
11
Check the inverter solenoid assembly for proper operation.
Caution: When performing motor tests,
ensure that all cover and door interlock
switches are overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Scanner Motor Tests.
4. Touch Inverter solenoid.
Does the above component operate properly?
Go to step 13. Go to step 12.
12
Check the inverter solenoid assembly for proper
connection.
Is the above component properly connected?
Replace the
inverter solenoid
assembly.
Go to “Inverter
solenoid
assembly
removal” on
page 4-139.
Replace the
connection.
Step Check Yes No