4-254 Service Manual
7510
4
Update the following settings using the newly converted values from step 2 for all newly installed
developer units:
Sensitivity gradient
Sensor output reference
1. Enter the Diagnostics Menu.
2. Touch ENGINE ADJUST.
3. Touch ATC Sensor Adjust Values
4. Enter new values.
5. Touch Submit.
Warning: This procedure must be done for all new developer unit assemblies being installed or print
quality problems may occur.
5
Note: Ensure that all photoconductor unit assemblies are
installed before performing this step.
Finalize the newly updated settings.
1. Enter the Diagnostics Menu.
2. Touch ENGINE ADJUST.
3. Touch ATC Sensor Adjust Cycles
Does the above test pass?
The sensor (ATC)
setup is now
complete.
Ensure that the
photoconductor
unit assemblies
are installed
before performing
this test.
ATC VALUE CONVERSION CHART
Bar code number
(last 2 digits)
Sensitivity gradient default value Standard TC output default value
00 526 169
01 572 166
02 617 162
03 663 158
04 708 154
05 753 150
06 799 146
07 844 142
08 889 138
09 934 134
10 526 171
11 572 168
12 617 164
13 663 160
Step Check Yes No