4-270 Service Manual
7510
2
Perform the center setup:
1. Enter the Diagnostics Menu.
2. Touch ENGINE ADJUST.
3. Touch RegCon adjust
4. Touch Control setup cycles
5. Touch Center setup
Does the above test pass?
Move the image
density sensor
back to its original
position.
The color
registration
(RegCon)
procedure is now
complete.
Go to step 3.
3
The image density sensor is not properly set in the center
position. Ensure the image density is placed in the center
position.
Is the image density placed in the center position.
Go to step 2. Repeat step 3.
Center setup
Step Check Yes No