EasyManuals Logo

LSIS sv-ig5a User Manual

LSIS sv-ig5a
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
4-12
Changing parameter value in Input/Output group
When changing the parameter value of F28 from 2 to 5
FU group 1
1
-. In F0, press the Ent () key once.
2
-. Check the present code number.
-. Increase the value to 8 by pressing the Up () key.
3
-. When 8 is set, press the Left () key once.
4
-. 0 in 08 is active.
-. Increase the value to 2 by pressing the Up () key.
5
-. 28 is displayed
-. Press the Ent () key once.
6
-. The parameter number F28 is displayed.
-. Press the Ent () key once to check the set value.
7
-. The preset value 2 is displayed.
-. Increase the value to 5 using UP key ().
8
-. Press the Ent () key.
9
-. Code number will appear after 5 is blinking. Parameter change is
complete.
-. Press either Left () or Right () keys.
10
-. Moving to first code of Function group 1 is complete.
The above setting is also applied to change parameter values in function group 2 and I/O
group.
For Service Call 800-848-2504
For Service Call 800-848-2504