EasyManuals Logo

LSIS sv-ig5a User Manual

LSIS sv-ig5a
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
5-8
Function group 1
LED
display
Address
for
commun
ication
Parameter
name
Min/Max
range
Description
Factory
defaults
Adj.
during
run
Page
F66
A242
[Up-down
step
frequency]
0~400
[Hz]
In case of choosing F65 as a 1 or 2, it means
increase or decrease of frequency according
to up-down input
0.00
X
8-5
F70
A246
[Draw run
mode
select]
0~3
0
Inverter doesnt run as a draw
mode
0
X
8-28
1
V1(0~10V) input draw run
2
I(0~20mA) input draw run
3
V1(-10~10V) input draw run
F71
A247
[Draw rate]
0~100
[%]
Sets rate of draw
0.00
0
8-28