Page #69 background image
5-21
Input/output group
LED
display
Address
for
communic
ation
Parameter
name
Min/Max
range
Description
Factory
default
Adj.
during
run
Page
I42
A42A
[Multi-
Accel time
5]
7.0
I43
A42B
[Multi-
Decel
time 5]
7.0
I44
A42C
[Multi-
Accel time
6]
8.0
I45
A42D
[Multi-
Decel
time 6]
8.0
I46
A42E
[Multi-
Accel time
7]
9.0
I47
A42F
[Multi-
Decel
time 7]
9.0
I50
A432
[Analog
output
item
select]
0 ~ 3
Output
item
Output to 10[V]
0
O
9-6
200V
400V
0
Output
freq.
Max frequency
1
Output
current
150 %
2
Output
voltage
AC 282V
AC 564V
3
Inverter
DC link
voltage
DC 400V
DC 800V
I51
A433
[Analog
output
level
adjustmen
t]
10~200
[%]
Based on 10V.
100
O
9-6
I52
A434
[Frequenc
y
detection
level]
0 ~ 400
[Hz]
Used when I54 or I55 is set to 0-4.
Cannot be set higher than F21.
30.00
O
9-7
I53
A435
[Frequenc
y
detection
bandwidth
]
10.00
O
I54
A436
[Multi-
function
output
terminal
select]
0 ~ 19
0
FDT-1
12
O
9-8
1
FDT-2
2
FDT-3
9-9
3
FDT-4
17
I55
A437
[Multi-
function
relay
select]
4
FDT-5
9-10
5
Overload (OLt)
9-10
6
Inverter Overload (IOLt)
7
Motor stall (STALL)
For Service Call 800-848-2504
For Service Call 800-848-2504

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS sv-ig5a and is the answer not in the manual?

LSIS sv-ig5a Specifications

General IconGeneral
BrandLSIS
Modelsv-ig5a
CategoryInverter
LanguageEnglish

Related product manuals