XGB Analog edition manual
15 - 12
(c) Input items
The items to set in the built-in PID function parameter window and the available scope
of them are summarized in below table.
Set the operation mode of PID control.
Set the operation direction of PID control.
Prevention of dual
integral accumulation
Set whether to allow dual integral accumulation.
Set whether to allow PWM output of maneuver
value.
Set the operation cycle time of PID control
cycle.
Set target control value.
Limiting change of
present value
Set the limited change of present value per
operation cycle.
Limiting change of
maneuver value
Set the limited change of maneuver value per
operation cycle.
Set the max. maneuver value for control.
Set the min. maneuver value for control.
Set the manual maneuver value for control.
Set the deadband width of the set value.
Differential filter value
Set the filter coefficient of differential operation.
Set the junction to which PWM output is out.
P20 ~ P3F
(%QX0.0.0~%QX0.0.31)
Set the output cycle of PWM output.
Set the frequency of set value ramp.
Set the follow-up frequency of the present value
follow-up function.
Set the min. value of the input present value.
Set the max. value of input present value.
< Table 15.7 PID function parameter setting items >