Beta Draft Confidential
4-46 ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring ATM Logical Ports on Frame-based Modules
Defining ATM Network Interworking for Frame Relay NNI Logical Ports
Max Full Status 
Attempts
(
1-port 
ATM IWU 
OC-3c/STM-1 
and 1-port ATM 
CS DS3/E3
 
modules)
The number of RLMI full status inquiry attempts used to bring up the 
working interface. The default is 3 attempts. Enter a value greater 
than zero (0).
See Chapter 15 for more information about RLMI.
Note: Changing the value for this attribute does not admin down the 
logical port.
LMI Update 
Delay
Set a timer from 1 to 9 seconds to enable asynchronous LMI updates. 
The default is 3 seconds.
When you set this timer, the switch sends a signal (known as an event) 
to notify other CPEs when a circuit on this logical port goes up or 
down. The specified time interval creates a buffer. If the circuit 
recovers within this period of time, no event is issued.
• If you choose No Updates, the switch does not send a signal to the 
CPE.
• If you choose No Delay, the switch sends an update immediately 
to the CPE.
For example, if the network takes a significant amount of time to 
recover from trunk outages, increase the LMI update delay. This delay 
minimizes network downtime visibility to end-users.
Note: Changing the value for this attribute does not admin down the 
logical port.
DTE Poll Interval 
(sec): (5-30):
Specify the number of seconds between the transmission of status 
inquiry messages (T391). Set the DTE poll interval to a value that is 
less than the DCE poll verify timer on the attached device. (This value 
must be greater than 1/2 the value of the DCE poll verify timer.) The 
default is 180 seconds for one-to-one mapping.
DTE Error 
Threshold: (1-10):
Specify an error threshold (N392). This parameter is used with the 
DTE Events Count (N393) parameter. The Local Management 
protocol monitors the specified number of events for the DTE Event 
Count. If the number of events found in error exceeds the specified 
DTE Error Threshold, the link is declared inactive. The default value 
is 3.
DTE Event Count: 
(1-10):
Specify the number of events in a sliding window of events monitored 
by the network. The default is 4. An event is the receipt of a valid or 
invalid status message or expiration of the T391 timer.
For example, use the default DTE Error Threshold value of 3 and the 
default DTE Event Count value of 4. If three (N392) of the last four 
(N393) events are bad, the link is declared inactive. The link remains 
inactive until the network receives four consecutive error-free events.
Table 4-18. Add Logical Port: Link Management Tab Fields (Continued)
Field Action/Description