Table 18-5 lists the allowed QoS classes for the offnet circuit endpoints.
2. Complete the Traffic Type tab fields, as described in Table 18-6.
Table 18-5. Allowable QoS Classes
QoS Class ATM Endpoint Frame Relay Endpoint
VBR-RT X
VBR-NRT X
UBR X
VFR-RT X
VFR-NRT X
UFR X
You must configure Traffic Type attributes before choosing OK in the Add Offnet
Circuit dialog box to save the circuit configuration. Otherwise, the default values
for committed information rate (CIR), committed burst size (Bc), and excess burst
size (Be) will generate an error message.