EasyManua.ls Logo

Lucent Technologies CBX 500 - Page 648

Lucent Technologies CBX 500
888 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Beta Draft Confidential
17-561/19/05 ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring SVC Parameters
Configuring SVC Port Addresses
4 bits Quadrant information
B-STDX 9000 or CBX 500 switch
0x0
GX 550 ES (Extender Shelf)
0x1 - the GX 550 ES is
connected to quadrant 1 in the
GX 550 switch
0x2 - the GX 550 ES is
connected to quadrant 2in the
GX 550 switch
0x3 - the GX 550 ES is
connected to quadrant 3 in the
GX 550 switch
0x4 - the GX 550 ES is
connected to quadrant 4 in the
GX 550 switch
GX 550 Switch
0xa - Quadrant 1 in GX 550
0xb - Quadrant 2 in GX 550
0xc - Quadrant 3 in GX 550
0xd - Quadrant 4 in GX 550
8 bits Physical port information A range of 0x00 to 0xff represents
physical ports from 0 to 255.
1 - 64 => CBX, B-STDX, or CBX
1 - 16 => GX 550 without a
GX 550 ES
1 - 12 => GX 550 ES connected to
a GX 550 switch
16 bits Interface ID Ranges from 0x0000 to 0xffff
8 bits Selector ID Fixed - 0x00
Table 17-13. ESI Byte Assignments (Continued)
Number of
bits/bytes
Contents/Purpose Range/Interpretation
Note – The CBX 3500, CBX 500, and GX 550 switches support the automatic ESI
assignment feature for both VNN and PNNI. B-STDX 9000 switches only support the
automatic ESI assignment feature for VNN.

Table of Contents