EasyManua.ls Logo

Lucent Technologies CBX 500 - Page 794

Lucent Technologies CBX 500
888 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-81/19/05 ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Adjusting the CAC
Configuring the CAC
Beta Draft Confidential
a. In the Upper Limit (cells/sec) column of the SCR Limit Scale Factors field,
enter the Upper Limit (cells/sec) of the SCR range for which you want to
customize the amount of bandwidth reserved. You can specify up to ten upper
limits. The following list shows several examples.
This would give you the following ranges of SCR values:
Example 1 Example 2 Example 3
10,000 10,000 8,000
20,000 16,000 12,000
35,000 20,000 15,000
24,000 20,000
28,000 25,000
35,000 30,000
35,000
Range Example 1 Example 2 Example 3
1 0-10,000 0-10,000 0-8,000
2 10,001-20,000 10,001-16,000 8,001-12,000
3 20,001-35,000 16,001-20,000 12,001-15,000
4 20,001-24,000 15,001-20,000
5 24,001-28,000 20,001-25,000
6 28,001-35,000 25,001-30,000
7 30,001-35,000

Table of Contents

Other manuals for Lucent Technologies CBX 500

Related product manuals