EasyManua.ls Logo

MAHA POWERDYNO MSR Series - Calculate Engine Factor Fm

MAHA POWERDYNO MSR Series
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
BA053101-en
Pos: 143 /Tech nische D okumen tation/A lle G eräte/ Überschr iften/Üb ers chrifte n 1.1.1/M/ Übe rschr ift 1.1. 1: Mot orfak tor fm ber echne n @ 13\mod_1234268542057_75.docx @ 337401 @ 3 @ 1
2.10.6
Calculate Engine Factor fm
Pos: 144 /Te chnis che D okum ent ati on/ Leis tun gsm esst ech nik/ POWE R DYN O/0 523 01 LPS 3 000 R10 0/B A/I nhal t: 052 3 Mot orf akt or fm ber echne n @ 13\mod_1234268616541_75.docx @ 337427 @ @ 1
In most cases fm = 0.3 applies but this value can be changed.
The following equations are used:
Engine factor fm based on ISO 1585:
652,37
r
q
14,1.036,0 =
r
q
fm
2,37<
r
q
2,0=fm
65>
r
q
2,
1=
fm
Engine factor fm based on EWG 80/1269, SAE J1349 and JIS D1001:
6540
r
q
14,1
.036,
0 =
r
q
fm
40
<
r
q
3,0=fm
65>
r
q
2,1=fm
Pressure behavior of the supercharging:
E
L
P
P
r =
Specific fuel consumption based on SAE J1349:
4-Takt Motoren
nD
F
q
= .120000
2-Takt Motoren
nD
F
q
= .60000
with
fm Engine factor
r Pressure behavior of the supercharging
q Specific fuel consumption based on SAE J1349
p
L
Absolute boost pressure
p
E
Absolute pressure in front of the compressor
F Fuel flow (mg/s)
D Cubic capacity volume
n Engine RPM
Pos: 145 /-----F ormat- ----/M ANUE LLER UM BRUC H Seitenum bruch @ 0\ mod_1134403577687_0.docx @ 1277 @ @ 1

Table of Contents

Related product manuals