3 - 33
CHECK Emergency controls
IMPORTANT
Use of the platform if there is a malfunction is prohibited.
- Check that the emergency controls are working, 2-DESCRIPTION: RESCUE PROCEDURE.
CLEAN Fuel filter cartridge
IMPORTANT
Never smoke or approach with a flame when the fuel filter cartridge is being cleaned.
Never use the platform without the fuel filter cartridge or if it is damaged. If there is doubt about its condition,
500H: REPLACE: FUEL FILTER CARTRIDGE.
- Open the left-hand turntable cover.
- Clean the outside of the fuel filter
1
with a clean cloth.
- Turn the tap
2
to the position
OFF
.
- Unscrew the retaining ring
3
.
- Remove the tank
4
and the fuel filter cartridge
5
. Clean them with clean fuel,
LUBRICANTS AND FUEL.
- Check their condition.
- Check the condition of the fuel hoses and the hose clamps.
- Refit the fuel filter cartridge, tank and retaining ring.
- Bleed the fuel supply circuit OCCASIONAL MAINTENANCE.
- Close the left-hand turntable cover.
5
4
3
OFF
2
1
1
547399 (01/03/2019)