2 - 41
32
31
32 - OVERLOAD ALARM LIGHT
Illustration = second version.
The overload alarm is activated when the load in the basket has reached maximum
capacity:
- The light flashes and the audible warning sounds continuously.
- All controls are locked,
OPERATING THE PLATFORM: LOCKED CONTROLS.
To stop the overload alarm and unlock the controls:
• Remove excessive load.
31 - USE ON SLOPE BUTTON
Illustration = second version.
IMPORTANT
The platform could tip over when this function is used. Use with extreme caution.
- Press the button and hold it down to action the locked controls (except driving
forward and backwards) when the tilt alarm is activated. TILT/OSCILLATION
ALARM INDICATOR LIGHT.