2 - 40
30
30 - TILTING/OSCILLATION ALARM LIGHT
Illustration = second version.
The tilt alarm is activated when the platform is on a steep slope:
- The indicator light flashes (On = 0.6 seconds, Off = 0.4 seconds) and the audible
alarm sounds intermittently (On = 1 seconds, Off = 1 seconds).
- Some controls are locked,
OPERATING THE PLATFORM: LOCKED CONTROLS.
To stop the levelling alarm and unlock the controls:
• Fully retract the telescope.
• Fully lower the main arm.
• Fully lower the secondary arm.
• Move platform to a level surface.
From machine no. 949267:
The oscillation alarm is activated when an oscillating axle locking fault is detected:
IMPORTANT
If the fault persists, consult your dealer.
- The indicator light flashes (On = 0.4 seconds, Off = 0.4 seconds) and the audible
alarm sounds intermittently (On = 0.4 seconds, Off = 0.4 seconds).
- Some controls are locked, OPERATING THE PLATFORM: LOCKED CONTROLS.
To stop the oscillation alarm and unlock the controls:
• Fully retract the telescope.
• Fully lower the main arm.
• Fully lower the secondary arm.
• Fully lower the jib.
• Move platform to a level surface.
Press the key OK
on the ground control panel so that the oscillation
alarm is no longer displayed. This action is recorded in the faults history.