From machine no. 949267:
The light flashes and the audible alarm sounds when the fuel level is low.
3 alarm levels:
LOW FUEL LEVEL ALARM LIGHT HORN
Level 1
On = 0.8 seconds 3 beeps (ON = 0.6 seconds, OFF = 0.4 seconds)
Off = 0.4 seconds repeated every 10 minutes
Level 2
On = 0.4 seconds 3 beeps (ON = 0.4 seconds, OFF = 0.4 seconds)
Off = 0.4 seconds repeated every minute
Level 3*
On = 0.3 seconds 3 beeps (ON = 0.4 seconds, OFF = 0.4 seconds)
Off = 0.2 seconds repeated every 10 seconds
*: It is no longer possible to raise the main/secondary arms, extend the telescope, raise the jib, tilt the basket upwards/
downwards, turn the turntable and turn the basket for more than 2 seconds at a time.
35 - BACKUP PUMP BUTTON
Illustrations:
#1
= first version,
#2
= second version.
RESCUE PROCEDURE.
35
#2
35
#1
34 - LOW FUEL LEVEL ALARM LIGHT
Illustration = second version.
Up to machine no. 949266:
The indicator light is lit when the fuel level is low and the audible alarm sounds: 3 beeps
every 10 minutes.
NOTE: There are approximately 8litres of fuel left when the light comes on.