DESCRIPTION
SERVICE MANUAL NUMBER 22
90-860074--1 FEBRUARY 2002 Page 5A-11
Analog Value Conditioning
The analog value conditioning is subdivided into two parts: sampling the analog signals and
scaling and checking the raw values.
The following analog values are made available as messages by the analog value
conditioning circuits of the ECM:
Water temperature
Air temperature
Fuel temperature
Intake manifold pressure (boost pressure)
Atmospheric pressure
Throttle Position (TP)
Instrumented Injector Needle movement
TP current
Reference voltage
Battery voltage
ANALOG VALUE SAMPLING
Sampling saves the results of the periodic analog/digital conversion as raw values. The
stored values are evaluated at a later time.
In addition to periodic signal sampling there is also an active speed-synchronous sampling.
Upon starts, the speed-synchronous sampling conversion that may be running is stopped.
In the next signal sampling period, the discontinued conversion is again started.