Automatic Maintenance Function
4-26
Setting the Cleaning Intervals
The cleaning type and the interval between each cleaning operation are set.
1
Select [AUTO MAINT.] of the maintenance menu.
(1) Press the key in LOCAL.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [AUTO MAINT.].
(4) Press the key.
2
Press to select [CLEANING].
3
Press the key.
4
Press to set the interval between each
cleaning operation.
Set value : OFF, Lv.1, Lv.2, Lv.3
As the LEVEL increases, the interval between each operation gets
shorter.
5
Press the key.
When you set other than “OFF” in the Step 4, the cleaning type
selection screen is displayed.
6
Press to select a cleaning type.
Set value : NORMAL, SOFT, HARD
7
Press the key.
8
Press the key several times to end the setting.
AUTO MA I NT .