Warning / Error Messages
5-16
SYSTEM HALT
Message Cause Solution
Ink heater PCB fuse is out.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
UVLED diver circuit board fuse has
blown.
UVLED circuit board is very hot.
There remains received data that has
not yet been printed.
Execute the data clear function.
(P.2-17)
The number of mounted heads is 0
(zero).
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
The ambient temperature is out of the
usable temperature range (too low).
Adjust the ambient temperature of the
installation place.
The ambient temperature is out of the
usable temperature range (too high).
Message Solution
Turn off the main power to the machine and turn it on after a while.
Check the number and contact your local distributor to call for service.
(“000” is the error
No.)
ERROR 7 1 9
InkHeaterPCB Fuse:12
ERROR 7 1A
UV-DRV Fuse :******
ERROR 7 1 1
LED OVHT 0 * * 0 * *
ERROR 9 0 2
DATA REMA I N
ERROR 9 0 d
NO HEAD SE L ECT
ERROR 9 1 0
ENV I RONMENT TEMP ( LO )
ERROR 9 1 1
ENV I RONMENT TEMP ( H I )
SYSTEM HALT
00 0 : MESSAGE