EasyManua.ls Logo

MIMAKI JFX200-2513 - Changing Origin with FUNCTION Menu

MIMAKI JFX200-2513
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-3
1
1
3
Convenient use
5
6
Changing origin
Changing origin with FUNCTION menu
To precisely set the origin of coordinates, set its X- and Y- coordinates from the FUNCTION menu. This setting
value becomes the origin position (0, 0).
1
Press the key in LOCAL.
2
Press to select [ORIGIN] and press the
key twice.
X-axis offset value setting screen is displayed.
3
Press to input the X offset value.
Setting the origin position of X-axis.
4
Press the key.
5
Press to select [Y OFFSET] and press the
key.
6
Press to input the Y offset value.
Setting the origin position of Y-axis.
7
Press the key.
8
Press the key several times to end the setting.
The set value is not cleared by cutting the power.
FUNCT I ON
VIEW [ENT]
ORIGIN 3100 mm
XOFFS : 3100 mm
ORIGIN 1300 mm
XOFFS : 1290 mm
OR I G I N
SELCT : X OFFSET
OR I G I N
SELCT : Y OFFSET
ORIGIN 2500 mm
YOFFS : 2090 mm
OR I G I N
SELCT : Y OFFSET