5-14
Message Cause Solution
USB device initialization failure.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Occurrence of a time out error on a
USB device.
An excessive load was applied to the X
motor.
An excessive load was applied to the Y
motor.
An error due to an excessive current of
the X motor was detected.
An error due to an excessive current of
the Y motor was detected.
Time to replace the brush of Y motor
has come.
• The brush of Y motor shall be replaced.
Contact a distributor in your district, our
office, or our call center.
The media jam occurs. • Remove the media and reset it.
A HDC position counter error occurred.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Y-origin could not be detected.
Abnormal linear scale.
X-origin could not be detected.
The value of the negative pressure
sensor is abnormal.
• Perform “PRESSURE ADJUST” ( P.5-
7) of the maintenance. If you cannot adjust
it to the normal value, or, even if you per-
form, it may be displayed, contact your
local distributor to call for service.
The value of the positive pressure sen-
sor is abnormal.
The liquid level sensor abnormality of
the sub tank has been detected.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Though a certain amount was con-
sumed, there is no change in the sub
tank sensor High.
• Perform “SUB TANK” ( P.5-6) of the
maintenance. Even if you performed this,
when the message is displayed, contact
your local distributor to call for service.
Though a certain amount was con-
sumed, there is no change in the sub
tank sensor Low.
Overflow from the sub tank has been
detected.