4-16
6
Clean the cap rubber and cap rubber cover.
• Wipe off the ink sticking to the cap rubber and cap rubber
cover with a clean stick dipped in cleaning solution for
maintenance. Wipe off so that cleaning solution for
maintenance will not remain.
• At this time, the discharge passage is cleaned automatically.
7
Press the key.
8
Fill up the cap with cleaning solution for
maintenance, using a dropper.
• Fill the cap with the cleaning solution just before the solution
overflows from the cap.
9
Press the key.
• The cleaning solution filled in the cap is absorbed.
• The screen on the right is displayed while the cap is left in a
cleaning solution
• It returns to the step2 after the duration.
• Until washing liquid is filled, [COMPLETED (NEXT): ENT] is displayed on the screen.
After the work up to the Step 8 is completed, press the key. If you press the
key before washing liquid is filled, the carriage returns to the original position.
• When nozzle missing is not cleared even after this washing is carried out several times, contact the
distributor in your region or our service office.