4 - 6 Operator’s Manual
4 Setup
Measure Parameter
Controls are as follows:
Trace Cursor Speed
Set the cursor speed during tracing.
LV Cube/Teichholz/Gibson
Set the tools used in the Cube/Teichholz/Gibson study.
Comment
Set whether to clear comments and bodymark:
Follicle
Set the method for calculating the follicle.
PW Measure
PW Velocity Measure Displays Absolute Value: All measurement results in PW mode are absolute
values based on the unit of velocity after checking this item.
Item Description
Cursor Type Type of cursor displayed on the measurement caliper and results window.
Value options:
Number: the cursor always displays as “+” while different measurements
are marked with numbers.
Symbol: the cursor displays sequentially in 8 symbols to identify different
measurements.
Cursor Size The size of the cursor.
Heart Beat The number of cardiac cycles in the heart rate calculation. (In heart rate
measurement, the number of cardiac cycles should match the preset number.)
Ellipse's style To set the style of ellipse calipers.
Trace line style To set the style of trace line calipers.
Cursor Line
Display
If unselected, the connecting line between the measuring ends will be hidden
after measurement.
Ellipse CrossLine
Display
If unselected, the measuring axis within the ellipse area will be hidden after
measurement.
Clear results while
deleting caliper
Uncheck. The image is unfrozen or the image mode is changed after the
measurement is completed. The measurement results are saved if the caliper
is cleared.
Unit Setting To set the measurement unit.
Item Description
Clear comments while unfreezing
image or changing probe/exam
To set whether to clear comments while unfreezing image or
changing probe/exam.
Clear Bodymark upon Unfreeze To set whether to clear bodymark whiling unfreezing image.
Voice comment enabled To set whether to enable voice comment feature.

Table of Contents

Other manuals for Mindray Resona R9 Exp

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray Resona R9 Exp and is the answer not in the manual?

Mindray Resona R9 Exp Specifications

General IconGeneral
BrandMindray
ModelResona R9 Exp
CategoryDiagnostic Equipment
LanguageEnglish

Related product manuals