SECTION
MITL9105/911
O-096-350-NA
GENERIC REVISION
ATT
IN1
RCL
DID MAN
SOURCE
I
DESTINATION
I
I
ITERNAL FIRMWARE CONSOLE NUMBER
CODE
figure 3-3 Typical Identification Display
speech path and receiver for use and display their status on the
Scanner
card.
3.10 Most of these features require a special access code (the Main-
tenance Function code), which will normally be
“555’,
but may
be different if necessary to avoid number plan conflicts. This document
assumes the use of the code 555.
Note:
The rotary switches on the tone control card (slot 18) should
be set to 8888 when the test line is not being used for
maintenance purposes.
Direct Trunk Access
3.11
The test line (or console) dials 555 + 2 + nnn where “nnn” is the
3-digit equipment number of the trunk, including leading zeros.
Reorder tone indicates that the equipment number is not that of a
trunk Busy tone indicates that the trunk is busy; otherwise the line is
connected to the trunk If the trunk is a member of a group pro-
.J’
..
grammed ‘Wait for Dial Tone”, the connection is not made until dial
‘\
tone is received.