SECTION
MITL91
OW911
O-096-350-NA
TABLE
4-7
c
EXTENDED PROGRAMMING TOLL PROGRAMMING ERRORS
Error
Applies to:
EO
All modes
Meaning
Invalid key pressed. Consult MAP for correct
procedure. System Option 292 may
not
be
enabled.
El
Absorb Plan mode
Trunk Group mode
Control Plan mode
Number is not within the range of the
parameter being defined. Press
parameter key defined and enter new correct
number.
E2
E3
All modes
.-
Control Plan mode
Table mode
An attempt was made to leave the current mode
after some parameters were changed but before
ENTER or CANCEL was pressed. ENTER may be
used to write the new programming information
back to the non-volatile RAM, or use CANCEL to
ignore all programming changes made since the
last time ENTER was pressed.
The number entered is not valid.
E4
Table mode The table entry code is invalid for the table
programmed. This occurs in the following
situation:
1. A code of more than three digits in length for
an 800-entry or 20-range table.
2. A code not in the range of 200-999 for an
800-entry table.
E5
E7
Table mode
Config/lnit
mode
3. A code which already exists or a code which
would be ambiguous in conjunction with the
existing table entries, for a 4-entry table.
The table is full and cannot hold the entry.
Initialization is not allowed because the Tone
Control card switches are not 7776 or the system
is not idle.
E9
Configuration mode
A hardware failure was detected while clearing
the extended customer non-volatile RAM.
Page 44