SECTION
MITL91
OS/91
lo-096-350-NA
TABLE 4-5
STANDARD PROGRAMMING ERROR CODES
Error
Kev
Code Cause
Affected
Kev
Flashing Meaning
Action
Required
EO
Invalid key
ALL None The last key pressed Check procedure and
pressed.
is invalid at this time. press correct
key.
El Invalid number. ALL None The number entered is Press key associated
out-of-range or contains with entry and
corrupted data. re-entry number.
E2
Key other than LAMP TEST, ENTER, An attempt was made to Press ENTER to transfer
ENTER or COS OPTION, CANCEL leave the current mode, the data to permanent
CANCEL FEATURE,
after some parameters
or CANCEL to remove
pressed. EXTN NUMBER, were changed. but before the data from the
TRUNK HUNT
ENTER or CANCEL temporary store.
GROUP,
was pressed. ENTER
TRUNK GROUP,
may be used to
NEXT, EQPT
write the new
NUMBER
programming information
back to the non-volatile
RAM, or use CANCEL to
ignore all programming
changes made, since the last
time ENTER was pressed.
E3
Access code has
HUNT GROUP, ACCESS Attempting to enter Press ACCESS CODE
not been entered.
TRUNKGROUP CODE members into a key and enter
hunt or trunk group required access code.
before an access code has
been assigned to the group.
E4
The extension EXTN, None The extension number of Check code entered:
number or access ACCESS access code entered is 1. If code is correct,
code entered is CODE already assigned to an terminate entry,
already assigned. extension, feature, hunt remove other
group or trunk group.
appearance of code
In Trunk mode, an attempt and re-enter all new
is made to delete a
data.
member of a trunk group. 2. If code is incorrect,
Equipment Numbers desired press key associated
must be entered. with entry and
In Trunk Group mode, re-enter extension
an attempt is made number or access code.
to place a trunk into a trunk
group while that trunk is
currently programmed into
another trunk group.
Callback and Executive
Override conflict; i.e., trying
to enter a Callback code
while same code is assigned
to Executive Busy Override
and vice versa.
E5
Number entered EXTN NUMBER, None The extension number or Check entry. Press
contains incorrect ACCESS CODE access code is in conflict key associated with
number of digits with the existing numbering entry and re-enter
or conflicting plan. Attempting to add number.
option enabled an option to a COS
in this COS. in which a conflicting option
is enabled. Attempting to
add a System Option when
a conflicting option exists.
Page 40