SECTION
MITL9105/91
lo-096-350-NA
TABLE 4-5 (CONT’D)
STANDARD PROGRAMMING ERROR CODES
Error
Kev
Code Cause Affected
Kev
Flashing Meaning
Action
Required
E6
Incorrect
EQPT
NUMBER None Attempting to assign Remove conflicting
equipment an equipment number option:
number entered. that is: (a) Assign equipment
-
undefined number correctly
-
defined as a trunk
to an extension hunt
(JI~,‘,“,‘Y
new equipmer
group or extension
-
defined as an extension to
a trunk group or a trunk
-
an extension with
message registration to hunt
group or pickup group.
An equipment number
assigned to an extension
must be deleted as an
extension, before being
programmed as a trunk An
equipment number assigned
to a trunk must be deleted
as a trunk, before being
programmed as an
extension.
E6
In extension EQPT NUMBER None The equipment number Enter correct
mode, the selected to be equipment number
equipment programmed has already or delete
number is
been set programmed in conflicting
SUPERSET
assigned as: a
the
SUPERSET
set programming.
call announce
programming as a
port, a
SUPERSET
set, a single
programmed
line set with appearances
SUPERSET
set or or an announce port.
a single line set
with appearances.
E6
In trunk mode EQPT NUMBER None The trunk equipment
the trunk
Delete appearances
number already has on the
SUPERSET
set.
selected has an appearance
appearances on
on a
SUPERSET
set.
a
SUPERSET
set.
E7
System is busy. ENTER None
la) Attempting to initialize (a) Wait until system is
a system while system is idle.
in use.
(b)
Attempting to change
(b)
Wait until extension
data of an extension or trunk is idle.
or trunk while that extension
or trunk is in use. it must be
idle or busied-out.
Extension has a ENTER None
-
A valid message
message register
Zero message register,
register exists for
that is not zeroed
reset message waiting
this extension. or Do Not Disturb
or has a message
-
Extension has a
waiting, or has
and reprogram.
message waiting or
Do Not Disturb
Do Not Disturb set.
set.
Page 41