FX Series Programmable Controlers Applied Instructions 5
5-166
M8145 : Y000 pulse output stop (immediate)
M8146 : Y001 pulse output stop (immediate)
M8147 : Y000 pulse output monitor (BUS/READY)
M8148 : Y001 pulse output monitor (BUS/READY)
g)When a Mitsubishi MR-H or MR-J2 servo amplifier equipped with absolute position detection
function is used, the current position of the servo can be read by FNC 155 (ABS).
Dog search function is not supported. Start zero return from the front side of the Near point
signal.
Attention should be paid to the instruction drive timing.