FX Series Programmable Controlers Applied Instructions 5
5-169
f)Related device numbers.
D8145 : Bias speed adopted when either FNC158, DRVI or FNC159, DRVA are executed
D8147 (upper digit) & D8146 (lower digit) : Maximum speed when FNC156, FNC158 or
FNC159 are executed 100~100,000Hz.
D8148 : Acceleration/Deceleration time adopted when FNC156, FNC158 or FNC159 are
executed.
M8145 : Y000 pulse output stop (immediate)
M8146 : Y001 pulse output stop (immediate)
M8147 : Y000 pulse output monitor (BUS/READY)
M8148 : Y001 pulse output monitor (BUS/READY)
• Attention should be paid to the instruction drive timing.