FX Series Positioning Controllers Program format 5
5-37
5.6.14 cod 76 (CANC): Compensation cancel
c
CANC
The compensations cod73 to cod75 above are canceled.
Program example
cod91 (INC); Specifies the incremental travel method.
cod00 (DRV) Moves the machine to Point A.
x1000;
cod73 (MOVC) Compensates the travel.
x10; Sets the X axis compensation value to "10".
cod00 (DRV) Moves the machine to Point B.
x1500;
cod76 (CANC) Cancels compensation.
Acceleration is determined by PARA. 8 and PARA. 9.
The operation speed is determined by PARA. 4 (maximum speed).
Applicable models
Series name
Remarks
Basic
format
FX
2N
-20GMFX
2N
-10GM
FX
2N
-10GM
FX
2N
-20GM
Servo end check
Instruction group
Remarks
Travel compensation/Center point compensation/
Radius compensation/Compensation cancel
No
C
cod 76
CANC
cod 76
CANC
Compensation cancel
cod 76
CANC
➀➀
1015001000
PARA.8
PARA.9
PARA.4
Speed
Present
position
Point B
Point A