Wiring 3
3-1
3. Wiring
This section describes the wiring related to the positioning unit.
After finishing wiring, it is recommended to check the wiring by JOG operation before writing a
program. (At this time, set the positioning unit to the MANU mode. The JOG speed is deter-
mined by the setting of PARA. 5.) (Refer to Paragraph 4.3.1.)
3.1 Wiring of Power Supply
When independently using the positioning unit
Perform common grounding to in the positioning unit and in the drive unit.
When power is supplied from another power supply to the FX-30DU-GM, perform common
grounding to in the FX-30DU-GM and in the positioning unit, and connect "24-" in
the power supply.
FX-30DU-GM
FX
2N
-10GM
FX
2N
-20GM
Extension block
for input (only in
FX
2N
-20GM)
*1
Class 3
grounding
DC24V
-15%
+10%
DC24V
-15%
+10%
Drive unit
*1 The name is different such as ,
FG
and
PE
in each drive unit.