FX Series Positioning Controllers Wiring 3
3-10
3.2.3 Operation input wiring
*1:In simultaneous 2-axis operation, connect either of the X and Y axes.
*2:In AUTO mode (while the MANU input is OFF), the input terminals [ZRN], [FWD] and [RVS]
can be used as general purpose inputs.
Manual forward rotation command. When this
is ON for a short time, the machine jogs by 1
step (minimum command unit).
123
+
-
+
-
+
-
STEP
START
STOP
RVS
FWD
ZRN
3
1
2
5
4
13
3
11
1
12
15
5
14
4
*2
*2
2
X axis: Pins 11 to 15
A
M.A
A
A
M.A
M.A
M.A
*1
*1
*2
Operation panel
Manual machine zero return command.
Stop operation. Resets error occurrence.
Starts automatic operation.
Single-step operation.
(Input No. is specified by parameters.)
Program No.
(Input No. is
specified by parameters.)
Setting for other various interval specification
data.
FX
2N-10GM
CON1
Y axis: Pins 1 to 15
Manual forward rotation command. When this
is ON for a short time, the machine jogs by 1
step (minimum command unit).
M: Manual A: Auto
FX
2N
-20GM
CON2