FX Series Positioning Controllers Special auxiliary relays and Special data registers 6
6-3
6.2 Special auxiliary relays list
Special auxiliary relays (specification inputs) for writing. (Y axis not available in FX
2N
-10GM.)
Attribute
W: This special auxiliary relay can be used only for write.
R/W: This special auxiliary relay can be used both for write and read. It turns on when a
command input is given from an external input terminal.
*1 Not defined in the FX
2N
-20GM. (Refer to Section 5.4.3)
In the simultaneous 2-axis mode (available only in the FX
2N
-20GM), even if the single-step
mode command, the start command, the stop command or the m code OFF command is
given only to the X or Y axis, it is valid for the both axes.
The ON/OFF status of the special auxiliary relays for command inputs are continuously
monitored by the CPU inside the positioning unit.
When the power is turned ON, each special auxiliary relay is initialized to OFF.
Table 6.1: Special auxiliary relays list
X axis Y axis Subtask Attribute Description
M9000 M9016 M9112
R/W
Single-step mode command.
When these special Ms
are driven by a main task
program (simultaneous 2-
axis program or X/Y axis
program) or subtask pro-
gram, they function as
substitute commands for
input terminal commands
of the positioning unit.
M9001 M9017 M9113 Start command.
M9002 M9018 M9114 Stop command.
M9003 M9019
m code OFF command.
M9004 M9020
Machine zero return command
M9005 M9021
FWD JOG command.
M9006 M9022
RVS JOG command.
M9007 M9023 M9115 Error reset.
M9008 M9024
Zero return axis control.
M9009 M9025
Not defined
M9010 M9026
Not defined.
M9011
M9027
to
M9030
M9116
to
M9125
Not defined.
However, M9118 functions as
shown on the next page.
M9012
M9013
M9014
W
16-bit FROM/TO mode (gen-
eral purpose/file register).
M9015
Continuous path mode. FX
2N
-10GM is not defined.
M9031 M9126 Not defined.

M9127 R/W Battery LED. Lighting control. FX
2N
-10GM is not defined.

M9132
Not defined.

M9133

M9134

M9135
M9036
to
M9040
M9041
to
M9045
M9046, M9047
M9160
*1

W
m code control during opera-
tion at multi-step speed
FX
2N
-20GM is not defined.