FX Series Positioning Controllers Introduction 1
1-24
1.7 Terminal Block
A terminal block converts the I/O area of a positioning unit or a connector type extension block
from a connector into a terminal block.
The following terminal blocks are available.
FX-16E-TB : For both input and output, 16 points, can be connected to
positioning unit and extension block
FX-32E-TB : For both input and output, 32 points, can be connected to
positioning unit and extension block
FX-16E-A1-TB : For only AC input, 16 points, can be connected to extension
block (cannot be connected to positioning unit)
FX-16EY
…
-TB (
…
= R, S or T): For only output, 16 points, can be connected to extension
block (cannot be connected to positioning unit)
FX-16EYT-H-TB : For only output, 16 points, can be connected to extension
block (cannot be connected to positioning unit)
You can use a terminal block for only AC input or for only output to convert a connector type
extension block connected to the FX
2N
-20GM into a terminal block. Have in mind that you can-
not connect such a terminal block to the I/O area of the positioning unit.
For the details of terminal blocks, refer to an instruction manual offered together with each ter-
minal block.
1.7.1 Outside dimensions
0
1
2
3
COM
COM
4
5
6
7
4
5
COM7
COM
1
0
1
2
3
COM
COM
4
5
6
COM
COM
0
1
2
3
COM
COM
MITSUBISHI FX-32E-TB
CN1
CN2
CN1 CN2
4
55
150
45
CN2
CN2
CN1
Lightly pull a hook to
attach/remove a terminal
block to/from a DIN rail.
DIN rail groove
(width: 35 mm)
CN1
FX-32E-TB
Terminal screw M3.5
1
0
1
2
3
COM
COM
4
5
6
7
COM
COM24+
24-
Terminal screw M3.5
4
55
150
Output indication
LEDs
(only in output type)
FX-16E-TB
FX-16EY
¨
-TB
FX-16EYT-H-TB
(
¨
=R,S,T)
FX-16E-A1-TB