FX Series Positioning Controllers Introduction 1
1-23
I/O cable FX-16E-500CAB-S
The figure above indicates the pin assignment when the connector is seen from the side on
which the positioning unit/extension block is connected (engaged).
Creation of I/O cable
We offer set parts of connectors for flat cables and unbound wires so that you can create I/O
cables by yourself.
Electric wires and crimp tools are to be prepared by you.
*1 When using unbound wires, you may not be able to smoothly insert them into a housing due
to dispersion in the sheath thickness. We recommend wires UL-1061.
Table 1.3: Creation of I/O cable
Model name and configuration of I/O connector
Applicable electric wire and tool
*1
Model name in
Mitsubishi
Included parts
(manufactured by
Daiichi Denshi)
Electric wire size
Crimp tool
(manufactured by
Daiichi Denshi)
FX
2C
-I/O-CON for flat
cable (10 connectors)
Crimp connector FRC2-
A020-30S
AWG28 (0,1 mm
2
), 1.27
pitch, 20-core
Main body 357J-4674D
Attachment 357J-4664N
FX
2C
-I/O-CON-S for
unbound wire (5 sets)
Housing HU-200S2-001
Crimp contact HU-411S
AWG22 (0.3 mm
2
)
357J-5538
FX
2C
-I/O-CON-SA for
unbound wire (5 sets)
Housing HU-200S2-001
Crimp contact HU-
411SA
AWG20 (0.5 mm
2
)
357J-13963
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Unbound wires
(Connected to a
relay terminal block,
general-purpose I/O
unit, etc.)
Connector on
positioning
unit/extension
block side
Protrusion

Table of Contents