FX Series Positioning Controllers Program format 5
5-26
5.6.4 cod 04 (TIM): Stabilization time
c
TIMER
Use this instruction to set the waiting time between completion of one instruction and execu-
tion of another.
d
Stabilization time (Dwell)
The increment is 10 msec. "k100" indicates a delay of 1
second.
*1: D2000 to D3999 are not available in the FX
2N
-10GM.
Table 5.13: Specification method
Specification method Set range
Direct specification k0 to k165,535
Indirect specification (16-bit) D0 to D6999 *1
Indirect specification (32-bit) DD0 to DD6998 *1
cod 04
T I M
Applicable models
Series name
Remarks
Basic
format
FX
2N
-10GM FX
2N
-20GM
cod 04
TIM
K
***
Stabilization time
cod 04
TIM
K
***
Stabilization time
FX
2N
-10GM
FX
2N
-20GM
Servo end check
Instruction group
Remarks
Stabilization time (Dwell)
TIMER
No
B
➀➁
➀➁
CHK
TIM
Time
CHK: Servo end check
TIM: Stabilization time