EasyManua.ls Logo

Mitsubishi FX2N-10GM - 11 FNC14 (RMOV): Reduction Transfer

Mitsubishi FX2N-10GM
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FX Series Positioning Controllers Program format 5
5-54
5.10.11 FNC14 (RMOV): Reduction transfer
When X24 is turned ON, the most significant bit in (S
x
) is transmitted to most significant bit in
(D
x
). Other bits are transmitted in turn from the least significant bit. b15 to b30 are ignored
and not transmitted.
01 11111000011101
0111111000011101
1111111111111111
(D4)
(D7, D6)
b0b15
b0b30 b15b16b31
FNC 14
RMOV
Applicable models
Series name
Remarks
K,H KnX KnY KnM D V,Z
Applicable
devices
and basic
format
Word
devices
FNC 14
RMOV
FX
2N
-10GM
FX
2N
-20GM
REDUCE
MOVE
RMOV
Reduction transfer
The data in the 32-bit device is transmitted to
the 16-bit device retaining the sign bit.
Drive
input
(not V.)
(not Z.)
16-bit operation
5 steps
Transfer
source
32-bit
Transfer
destination
16-bit
When X24 is turned ON, the contents of D6 and
D7 are transmitted to D4.
FNC 14
RMOV
D 6 D 4
X24
·