FX Series Positioning Controllers Introduction 1
1-15
*1:In the table 1.2, "(X)" indicates assignment for the X axis, and "(Y)" indicates assignment for
the Y axis.
FX
2N
-10GM...... CON1:Connector dedicated to I/O
CON2: Connector to connect a drive unit
FX
2N
-20GM...... CON1: Connector dedicated to I/O
CON2: Connector dedicated to I/O
CON3: Connector to connect a drive unit (for the X axis)
CON4: Connector to connect a drive unit (for the Y axis)
Description of two or more pin Nos. shown in the "Pin No." column such as COM1, COM2 and
VIN indicates that such pins are short-circuited inside.
• While the FX
2N
-20GM is performing simultaneous 2-axis operation, step mode command,
start command, stop command and m code OFF command are effective to the both axes
even if such a command is given to only either the X or Y axis.