FX Series Positioning Controllers Wiring 3
3-3
When connecting the positioning unit to the PLC
Perform common grounding to in the positioning unit and in the drive unit.
When power is separately supplied from another power supply to each of the PLC and the
FX-30DU-GM, perform common grounding to in the PLC, in the FX-30DU-GM and
in the positioning unit, and connect "24-" in each power supply.
At this time, connect an input common terminal in the AC type PLC, or connect "24-" in the
DC type PLC.
FX-30DU-GM
FX
2N
-10GM
FX
2N
-20GM
FX
2N
PC
(AC power supply)
L N
COM
Input
COM
24V DC
-15%
+10%
100V~240V AC
-15%
+10%
24V DC
-15%
+10%
FX-30DU-GM
FX
2N
-10GM
FX
2N
-20GM
FX
2N
PC
(DC power supply)
FX
2NC
PC
L N
24V DC
-15%
+10%
24V DC
-15%
+10%
24V DC
-15%
+10%
*1
Drive unit
*1
Drive unit
Extension block
for input (only in
FX
2N
-20GM)
Class 3
grounding
Extension block
for input (only in
FX
2N
-20GM)
Class 3
grounding
*1 The name is different such as ,
FG
and
PE
in each drive unit.