FX Series Positioning Controllers Parameters 4
4-13
PARA. 4: Maximum speed
Set the maximum speed in this parameter. When the speed is not specified in a positioning
program, the machine operates at the speed set here. Other speeds must be set to a value
equivalent to or less than this maximum value.
*1: 200 kHz or less when converted into pulses.
PARA. 5: Jog speed
Set the speed for manual operation (by FWD/RVS input ON or JOG+/- operation from a periph-
eral unit).
Set a value equivalent to or less than the value set to PARA. 4 above.
*1: 200 kHz or less when converted into pulses.
PARA. 6: Bias speed (Invalid during interpolation)
Set the speed adopted when the system is started.
*1: 20 kHz or less when converted into pulses.
Table 4.8: Maximum speed
FX
2N
-10GM FX
2N
-20GM
Mechanical system :0 to 153,000 (cm,/min, 10deg-min, inch/min)
*1
Motor system :0 to 200,000 Hz
Table 4.9: Jog speed
FX
2N
-10GM FX
2N
-20GM
Mechanical system :0 to 15,300 (cm,/min, 10deg-min, inch/min)
*1
Motor system :0 to 200,000 Hz
Table 4.10: Bias speed
FX
2N
-10GM FX
2N
-20GM
Mechanical system :0 to 15,300 (cm,/min, 10deg-min, inch/min)
*1
Motor system :0 to 200,000 Hz