(3) Range reference tables
Below are reference ranges to be used for saving and restoring offset/gain values.
(a) Reference table for CH1 Industrial shipment settings offset value (L)(Un\G202) to
CH4 Industrial shipment settings gain value (H)(Un\G217)
The reference values will vary depending on Pass data classification setting (Un\G200) (voltage or current).
(b) Reference table for CH1 User range settings offset value (L)(Un\G218) to CH4 User
range settings gain value (H)(Un\G233)
*1 This is the value that is stored in user range offset value at the time of shipping.
*2 This is the value that is stored in user range gain value at the time of shipping.
Address (decimal)
Description
Pass data
classification
setting
Reference value
(hexadecimal)
CH1 CH2 CH3 CH4
202,
203
206,
207
210,
211
214,
215
Industrial shipment settings offset
value
Voltage
Approx. 00000007
H
Current
Approx. 0000000E
H
204,
205
208,
209
212,
213
216,
217
Industrial shipment settings gain
value
Voltage
Approx. 00008011
H
Current
Approx. 00008018
H
Offset/gain value
Reference value
(hexadecimal)
Voltage
0V
Approx. 00000007
H
1V
Approx. 00000CD4
H
5V
Approx. 0000400C
H
10V
Approx. 00008011
H
Current
0mA
Approx. 00000007
H
4mA*
1
Approx. 00000CD4
H
20mA*
2
Approx. 0000400C
H

Table of Contents

Other manuals for Mitsubishi L Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi L Series and is the answer not in the manual?

Mitsubishi L Series Specifications

General IconGeneral
BrandMitsubishi
ModelL Series
CategoryEngine
LanguageEnglish

Related product manuals