GENERAL
1-14
Electrical
system
Stop
solenoid (1)
Working voltage 12V - ETR: 8V or less
Insulation resistance
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
Stroke 13.5 ± 0.5 mm [0.53 ± 0.02 in.]
Ambient temperature for use -40 to 120°C [-40 to 248°F]
Stop
solenoid (2)
Working voltage 12V - ETS: 10V to 15V
Insulation resistance
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
Stroke 10 ± 0.5 mm [0.39 ± 0.02 in.]
Ambient temperature for use -30 to 120°C [-22 to 248°F]
Stop
solenoid (3)
Working voltage 24V - ETR: 16V or less
Insulation resistance
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
Stroke 13.5 ± 0.5 mm [0.53 ± 0.02 in.]
Ambient temperature for use -40 to 120°C [-40 to 248°F]
Stop
solenoid (4)
Working voltage 24V - ETS: 20V - 30V
Insulation resistance
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
Stroke 10 ± 0.5 mm [0.39 ± 0.02 in.]
Ambient temperature for use -30 to 120°C [-22 to 248°F]
Table 1-2 Specifications of L3A, L3C and L3E (4 / 4)
Engine model L3A L3C L3E