SHOP MANUAL MT26-31 - 06.2005
Engine
Tier-3 710655-
Ch 1 page 24
From Main Menu, Select:
S6
Program E2 parameters
Read values
Make changes
Write values
Ecom standard settings code
CID Description Limits
Typical
Value
Unit
MT
Value
FE17 Low idle, ref engine speed 0 - 3200 650 rpm 650
FE21
Low idle, ref engine speed controller. 0 - 1 1
0 = use basic low idle, adjustable with CC-buttons
1 = Use FE17, not adjustable with CC-buttons
FE65
Oil temperature sensor on EMS available 0 - 1 0/1
0 = Not available
1 = Available
FE63
Use safety switch on accelrator pedal 0 -1 1 1
0 = Not available
1 = Available
FE67 Diesel fuel density, used only for fuel rate calculation 0 - 2000 840 g/litre 840
FD7D
Reduced high idle after start 0 - 1
0 = Enable
1 = Disable
FC8D
Type of governor 0 - 1 1 1
0 = RQ
1 = RQV
FCB1 High idle, ref engine speed 0 - 3200 23 - 2400 rpm 2420
FD6F
Coolant level sensor 0 - 1 0/1
0 = Not present
1 = From coordinator
FD6D
Reaction to low coolant level 0, 1, 2, 6
0 = Alarm only
1 = Torque limitation
2 = Stop engine
6 = Stop engine with override option