Page 32 of 48
User Manual
Operation Instructions
Subject to modifications
2.1A-30008-A04
LINCOLN GmbH & Co. KG • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Maintenance, Repair and Tests
Maintenance
The maintenance is essentially limited to refilling the res-
ervoir with clean lubricant in good time. However, check
regularly whether the lubricant is really dispensed to all
the lubrication points.
Also check the main lines and lubricant feed lines for
damage and replace them, if necessary.
6001a02
NOTE
Whenever work is done on the central-
ized lubrication system, particular atten-
tion should be paid to absolute cleanli-
ness. Dirt in the system will cause mal-
functions.
For cleaning the system use benzine or petroleum. Do not
use tri-, perchloroethylene or similar solvents.
Also do not use polar organic solvents such as alcohol,
methylacohol, acetone or similar.
Pump Filling
1011b93
Fig. 44 Fill pump reservoir
2 l, 4 l, 8 l - Reservoir
Fill the reservoir up to the ”Max.” mark via the filling nip-
ple, if any, or via the upper filling opening.
It is possible to use greases up to penetration class NLGI
grade 2.
6001a02
IMPORTANT
The grease or oil must be free from im-
purities and must not be liable to change
its consistency in the course of time.
4273a00
CAUTION!
If the pump is filled via the upper filling
opening, switch off the power supply
before starting filling.
1013A94
CAUTION!
Risk of bursting if the reservoir is over-
filled.
When filling the reservoir by means of
pumps with a large delivery volume do
not exceed the max. filling mark.
6001a02
NOTE
If the reservoir has been completely
emptied, the pump may require until 10
minutes before it operates with its full
output.