SHOP MANUAL MT26-31 - 06.2005
Engine
Tier-3 710655-
Ch 1 page 26
CID Description Limits
Typical
Value
Unit
MT
Value
FCA1
PTO mode 1, accelrator pedal effective 0 - 1 1
0 = Active
1 = Not active
FD11 PTO mode 4, max torque 0 - 5100 5100 rpm 5100
FE15
Low idle to adjust fuel adjustment. Droop function on
low idle
0 - 1
FCE3
Accelrator pedal value converted to reference engine
speed
0 - 3200 array x 4 rpm
480/2500/
2500/2500
FCF9 Accelrator break point for FCE3 0 - 100 array x 4 %
0/100/
100/100
FCE5 Droop values for different accelrator pedal values 0 - 8 array x 4
rpm/
mg/st
4,5/4,5/
4,0/0,5
FCFB Accelrator pedal breakpoint for FCE5 0 - 100 array x 4 %
0/20/80/
100
FD77
Voltage breakpoints for 0% and 100% for redundant
Accelrator pedal connected to input AUX_AN on EMS
100 - 4900 Array x 2
485/2693 mV 485/2693
FD73
Engine speed dependent friction torque. Breakpoints
in flash, 500, 1000, 1500, 2200 rpm
0 - 5100 array x 4 Nm 0/0/0/0
FD75
Engine speed and temperature dependant friction
torque. Breakpoints in flash, 500, 1000, 1500, 2200
rpm
0 - 5100 array x 4 Nm 0/0/0/0
FD71
Temp. breakpoints for 0% and 100% of fan friction
torque of FD75
0 - 150 array x 2 °C 80/100
FD13
Torque limit 2, extra torque curves for customer use.
Breakpoints for software version 2253: 1000, 1100,
1200, 1400, 1600, 1800, 1900, 2000, 2100, 2200,
2300, 2400
0 - 5100 array x 12 Nm 12 x 5100
FD15
Torque limit 3, extra torque curve for customer use.
Breakpoints for software version 2253: 1000, 1100,
1200, 1400, 1600, 1800, 1900, 2000, 2100, 2200,
2300, 2400 rpm
0 - 5100 array x 12 Nm 12 x 5100

Table of Contents

Related product manuals