A2 METERING DATA 5. ACTUAL VALUES
5-12
5.3.7
DEMAND METERING
y
'(0$1'#0(7(5,1*
y
>(17(5@#IRU#PRUH
Õ
ÕÕ
Õ
ENTER
ENTERENTER
ENTER
ESCAPE
ESCAPEESCAPE
ESCAPE
Ö
ÖÖ
Ö &855(17
'(0$1'=#######3#$PSV
RANGE: 0 - 100000
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
Ú
ÚÚ
Ú
5($/#32:(5
'(0$1'=#######3#N:
RANGE: 0 - 50000
NOTE: This message is not seen if VT Ratio is programmed as 'None'.
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
Ú
ÚÚ
Ú
5($&7,9(#32:(5
'(0$1'=#######3#NYDU
RANGE: 0 - 50000
NOTE: This message is not seen if VT Ratio is programmed as 'None'.
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
Ú
ÚÚ
Ú
$33$5(17#32:(5
'(0$1'=#######3#N9$
RANGE: 0 - 50000
NOTE: This message is not seen if VT Ratio is programmed as 'None'.
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
Ú
ÚÚ
Ú
3($.#&855(17
'(0$1'=#######3#$PSV
RANGE: 0 - 100000
NOTE: This message is not seen if VT Ratio is programmed as 'None'.
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
Ú
ÚÚ
Ú
3($.#5($/#32:(5
'(0$1'=#######3#N:
RANGE: 0 - 50000
NOTE: This message is not seen if VT Ratio is programmed as 'None'.
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
Ú
ÚÚ
Ú
3($.#5($&7,9(#32:(5
'(0$1'=#######3#NYDU
RANGE: 0 - 50000
NOTE: This message is not seen if VT Ratio is programmed as 'None'.
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
×
××
×
3($.#$33$5(17#32:(5
'(0$1'=#######3#N9$
RANGE: 0 - 50000
NOTE: This message is not seen if VT Ratio is programmed as 'None'.
DESCRIPTION:
The values for current and power demand are shown here. Peak Demand information can be cleared using the setpoint in S1 SR469
SETUP under CLEAR DATA. Demand is shown only for positive real and positive reactive power (+Watts, +vars).
5.3.8
ANALOG INPUTS
y
$1$/2*#,13876
y
>(17(5@#IRU#PRUH
Õ
ÕÕ
Õ
ENTER
ENTERENTER
ENTER
ESCAPE
ESCAPEESCAPE
ESCAPE
Ö
ÖÖ
Ö $QDORJ#,23#4
3#8QLWV
RANGE: -50000 to +50000 * Message seen only if analog input is programmed
*The alarm message will reflect the Analog Input name and units as programmed,
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
Ú
ÚÚ
Ú
$QDORJ#,23#5
3#8QLWV
RANGE: -50000 to +50000 * Message seen only if analog input is programmed
*The alarm message will reflect the Analog Input name and units as programmed,
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
Ú
ÚÚ
Ú
$QDORJ#,23#6
3#8QLWV
RANGE: -50000 to +50000 * Message seen only if analog input is programmed
*The alarm message will reflect the Analog Input name and units as programmed,
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
×
××
×
$QDORJ#,23#7
3#8QLWV
RANGE: -50000 to +50000 * Message seen only if analog input is programmed
*The alarm message will reflect the Analog Input name and units as programmed,
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
×
××
×
$QDORJ#405
3#3HUFHQW
RANGE: -5100 to +4900 * Message seen only if analog in diff 1-2 set to % Diff.
*The alarm message will reflect the Analog Input name and units as programmed,
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
×
××
×
$QDORJ#405
3#8QLWV
RANGE: -100000 to +100000 * Message seen only if analog in diff 1-2 set to Abs Diff.
*The alarm message will reflect the Analog Input name and units as programmed,
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
×
××
×
$QDORJ#607
3#3HUFHQW
RANGE: -5100 to +4900 * Message seen only if analog in diff 3-4 set to % Diff.
*The alarm message will reflect the Analog Input name and units as programmed,
Û
ÛÛ
Û
ESCAPE
ESCAPEESCAPE
ESCAPE
MESSAGE
MESSAGEMESSAGE
MESSAGE
×
××
×
$QDORJ#607
3#8QLWV
RANGE: -100000 to +100000 * Message seen only if analog in diff 3-4 set to Abs Diff.
*The alarm message will reflect the Analog Input name and units as programmed,
DESCRIPTION:
The values for analog inputs are shown here. The name of the input and the units will reflect those programmed for each input.
If no Analog Inputs are programmed in S12 ANALOG I/O, the following flash message will appear when an attempt is made to enter this
group of messages.
7+,6#)($785(##127
352*5$00('