Heat: The temperature at which the heaters begin to operate. This temperature must be
lower than the target temperature (at the target temperature, the heaters turn off).
Range: 1.0° to 90° C/ 34° to 194 F. Default: 78 (first day). 0 (all other days)
o
Low Alarm: Set the temperature at which an alarm is generated, signaling the barn
temperature is too low. The Low Alarm parameter must be lower than that day's target
temperature. Range: 1.0° to 90° C/ 34° to 194 F. Default: 70 (first day). 0 (all
other days).
o
High Alarm: Set the temperature at which an alarm is generated, signaling the barn
temperature is too high. The High Alarm parameter must be greater than that day's
target temperature. Range: 1.0° to 90° C/ 34° to 194 F. Default: 95 (first day). 0
(all other days).