7197 Series II Owner’s Guide Chapter 6: Commands
August 2011
157
M Bar Code D n, Length
65 UPC-A 48- 57 (ASCII numerals) Fixed Length: 11, 12
66 UPC-E 48- 57 Fixed Length: 11, 12
67 JAN13 (EAN13) 48- 57 Fixed Length: 12, 13
68 JAN8 (EAN8) 48- 57 Fixed Length: 7, 8
69 CODE 39 48- 57, 65- 90 (ASCII
alphabet),
32, 36, 37, 43, 45, 46, 47
(ASCII special characters)
d1 = dn = 42 (start/stop
code is supplied by
printer if necessary)
Variable
70 Interleaved 2 of 5
(ITF)
48- 57 Variable
(Even Number)
71 CODABAR
(NW-7)
65- 68, start code 48- 57,
36, 43, 45, 46, 47, 58
Variable
72 Code 93 0 - 127 Variable
(A748 Native
Mode
only)
73 Code 128 0-105
d1 = 103-105 (must be a
Start code)
d2 = 0-102 (data bytes)
(Stop code is provided by
the printer)
Variable
75 PDF417 0 – 255 Variable Length
(A748 Native
Mode
only)
76 GS1 DataBar
Omnidirectional
48 - 57 Fixed Length: 13
77 GS1 DataBar
Truncated
48 - 57 Fixed Length: 13
78 GS1 DataBar
Stacked
48 - 57 Fixed Length: 13
79 GS1 DataBar
Stacked
Omnidirectional
48 - 57 Fixed Length: 13
80 GS1 DataBar
Limited
48 - 57
[However d1= 48, 49]
Fixed Length: 13
81 GS1 DataBar
Expanded
32 - 34, 37 - 47, 48 - 57,
58 - 63, 65 - 90, 95,
97 - 122, 123
[However d1 = 40, 48 <=
d2 <= 57,
48 <= d3 <= 57 when
Variable length
(2 - 70)