7197 Series II Service Manual Chapter 3: Diagnostics
June 2011
39
** SET NUMBER OF DATA BITS ?
YES -> Long Click
NO -> Short Click
8 Data Bits* -> Long Click
7 Data Bits -> Short Click
** SET NUMBER OF STOP BITS ?
YES -> Long Click
NO -> Short Click
1 Stop Bits* -> Long Click
2 Stop Bits -> Short Click
** SET PARITY ?
YES -> Long Click
NO -> Short Click
No Parity* -> 1 Click
Even Parity -> 2 Clicks
Odd Parity -> 3 Clicks
Enter code, then hold Button DOWN
At least 1 second to validate
** SET FLOW CONTROL METHOD ?
YES -> Long Click
NO -> Short Click
Software (XON/XOFF) -> Long Click
Hardware (DTR/DSR)* -> Short Click
** SET DATA RECEPTION ERRORS OPTION ?
YES -> Long Click
NO -> Short Click
Ignore Errors -> Long Click
Print ‘?’* -> Short Click
Note: Press the Paper Feed Button for at least one second to validate the selection.
** SET RECEIVE BUFFER SIZE ?
YES -> Long Click
NO -> Short Click
4K Bytes * -> 1 Click
One Line -> 2 Clicks
8K Bytes -> 3 Clicks
12K Bytes -> 4 Clicks
Enter code, then hold Button DOWN
At least 1 second to validate
** SET DSR IGNORE FUNCTION ?
YES -> Long Click
NO -> Short Click
Enabled* -> Long Click